Skip to content
EVRINTH

Topic cluster

Liquid handling

Pipetting technique, tip choice, calibration checks and where manual and automated handling each fail.

26 articles

Gloved hands dispensing pink liquid into a 96-well plate with an 8-channel pipette

liquid handling

Multichannel technique on a 96-well plate

Compare single-channel and multichannel work on a 96-well plate, including tip seating, depth, angle, and the bias a loose tip leaves.

8 October 2026 · 7 min read

Close-up of a micropipette tip releasing a droplet into a microcentrifuge tube held in a gloved hand

liquid handling

Plate maps so a robot and a person agree

Compare a human plate map with a robot deck map so well identity, A1 orientation, replicates, and controls stay the same.

8 October 2026 · 7 min read

Close-up of a micropipette tip releasing a droplet into a microcentrifuge tube held in a gloved hand

liquid handling

Pre-wetting tips and volatile solvents

See why pre-wetting saturates the air cushion, why ethanol-class solvents still drip, and when positive displacement is the better class.

8 October 2026 · 7 min read

Close-up of a micropipette tip releasing a droplet into a microcentrifuge tube held in a gloved hand

liquid handling

Questions before a pipette enquiry

List volume range, displacement type, channels, tip family, calibration documents, and chemical exposures before you send a pipette enquiry.

8 October 2026 · 7 min read

Close-up of a micropipette tip releasing a droplet into a microcentrifuge tube held in a gloved hand

liquid handling

Serological pipettes are a different tool

Tell a blow-out serological pipette from a micropipette, use a controller, and retire a cracked pipette before it delivers a wrong millilitre.

8 October 2026 · 7 min read

Close-up of a micropipette tip releasing a droplet into a microcentrifuge tube held in a gloved hand

liquid handling

Small volumes near the bottom of the range

Diagnose noisy results at the bottom of a pipette range, move to a lower-range instrument, and watch pre-wetting and the first stop.

8 October 2026 · 7 min read

Close-up of a micropipette tip releasing a droplet into a microcentrifuge tube held in a gloved hand

liquid handling

Temperature of the liquid changes the volume

Equilibrate cold liquids and warm pipettes before you trust an air-displacement volume, and separate that error from a weighing drift.

8 October 2026 · 8 min read

Close-up of a micropipette tip releasing a droplet into a microcentrifuge tube held in a gloved hand

liquid handling

Tip fit is part of the measurement

Write a tip specification that names the cone, the family the pipette was tested with, and what a universal claim does not prove.

8 October 2026 · 7 min read

Close-up of a micropipette tip releasing a droplet into a microcentrifuge tube held in a gloved hand

liquid handling

Troubleshooting a dripping pipette

Name the seal, shaft, solvent, and piston causes of a dripping pipette, and keep that pipette out of service until it is checked.

8 October 2026 · 6 min read

Close-up of a micropipette tip releasing a droplet into a microcentrifuge tube held in a gloved hand

liquid handling

Troubleshooting scattered replicates

Name the technique, tip, temperature, mixing, and evaporation causes of scattered replicates, and what a method specification should record.

8 October 2026 · 7 min read