proteomics
TMT and iTRAQ as concepts
TMT and iTRAQ are isobaric reagent classes: one precursor mass, reporter ions for quantity, and ratio compression when other peptides are co-isolated.
8 October 2026 · 8 min read
Knowledge centre
Guides, method explainers and sourcing notes for research laboratories. Written by the EVRINTH Editorial Team from published methods, with catalogue links for enquiry rather than stock claims.
520 articles

proteomics
TMT and iTRAQ are isobaric reagent classes: one precursor mass, reporter ions for quantity, and ratio compression when other peptides are co-isolated.
8 October 2026 · 8 min read

liquid handling
Define the stops, tip seating, angle, pre-wet, and balance check a new student must show before a reagent kit is blamed.
8 October 2026 · 7 min read

laboratory safety
A certified cabinet is not a trained user. The record should show who was shown the airflow, the sash height, and the signs of failure.
8 October 2026 · 8 min read

gels and blotting
Compare wet, semi-dry and rapid transfer, then match nitrocellulose or PVDF, methanol and pore size to the protein you must keep.
8 October 2026 · 9 min read

buffers and water
Compare Tris with HEPES by the temperature of use. Tris pH falls as it warms; specify that temperature before you raise a reagent enquiry.
8 October 2026 · 8 min read

gels and blotting
Reason through a blank western in order: load, transfer, membrane face, antibody, azide, substrate, washes, then a true absence.
8 October 2026 · 8 min read

cytometry and microscopy
What no events means on a cytometer: clog, threshold, trigger, sheath, interlock, or a tube that is not actually sipping.
8 October 2026 · 7 min read

cytometry and microscopy
How to check shutter, filter cube, objective, correction collar, focus and exposure before calling a dim field a negative result.
8 October 2026 · 7 min read

liquid handling
Name the seal, shaft, solvent, and piston causes of a dripping pipette, and keep that pipette out of service until it is checked.
8 October 2026 · 6 min read

dna sequencing
A library number is not a molarity until the assay is named. How dye, adapter qPCR and a fragment trace disagree, and which disagreement matters.
8 October 2026 · 7 min read

chromatography
Work through a flat chromatogram by checking the lamp, wavelength, injection, leak, flow-through, and the integrator scale.
8 October 2026 · 7 min read

immunoassays
High background means the blank is loud. Separate a dirty blank from a plate that is loud in every well before you subtract and move on.
8 October 2026 · 9 min read